il_1588xN.899428233_f10h.jpg.jpg
Necklaces

White Europium phosphorescent Glow in the Dark Necklace , Science Jewelry

$29.99

What you will receive
The White europium based phosphorescent (glow in the dark) necklace, is the first ever Europium phosphorescent necklace. 
A unique high quality necklace that is sure to impress.
•The necklace is made from a strong silk/velvet material with a easy to use adjustable clasp. As seen in pictures 
•The length is 22 inches or 55.9cm, unisex.
The facts
•Produces a truly warm and beautiful glow. 
•Great chemistry gift 
•Amazing science gift 
Sweet Stocking stuffer, Christmas gift
•Europium powder can be recharged indefinitely just by holding it under bright light. (with the exception of extremes) Unlike other glow in the darks. 30 hours of glow time after being fully charged. Place on window seal for 45mins during the sunniest part of the day for 30 hours of glow time! (With a reduction in lumens over the course of the 30hrs)
•It is a difficult and expensive glow material to make due to the high cost of the exotic chemicals
•Based on the Rare-Earth element Europium. 

•This sample is great for fun science and Collections 
•This Phosphorescent material is at the cutting edge of chemical phosphorescent technology. 
•This is not a cheap weak Chinese glow powder that will not glow a week from now. 

DISCLAIMER ABOUT PICTURES 
•The pictures here do NOT do the glow justice, for the camera can not pick up all the light like our eyes can. 

Safety and toxicity 
•Non toxic 
•Non radioactive 
•Though it is not considerate a toxin do not ingest or inhale or the powder, If vial is broken. 

Shipping 
I offer fast free shipping to the U.S
International is additional

Quantity:
Add To Cart
il_1588xN.899428233_f10h.jpg.jpg
White europium necklace box re.jpg
europium necklace on chest 1 re.jpg
il_1588xN.899666298_57nt.jpg.jpg
necklace chain.jpg.jpg

Additional Info

MSDS from United Nuclear Scientific Supplies, LLC

125 N. 8th Street Klamath Falls, OR 97601 541-205-6855 sales@unitednuclear.com

_______________________________________________________________________

_______________________________________________________________________

Europium UltraGlow Phosphorescent Powder

_______________________________________________________________________

I. Product Identification

Synonyms: Strontium diluminate activated by europium Chemical Formula: SrAl2O4:Eu,Dy
CAS NO: 12004-37-4 .

24 HR EMERGENCY Telephone Number VelocityEHS (USA): 800-255-3924

II. Composition/Information on Ingredients

      Ingredient                                        Percent   Hazardous
      ---------------------------------------           -------   ---------

MSDS

Strontium diluminate activated by europium        99 - 100%    Yes

III. Hazards Identification

Emergency Overview

--------------------------

CAUTION! MAY CAUSE IRRITATION TO SKIN, EYES, AND RESPIRATORY TRACT. MAY AFFECT LUNGS. HARMFUL IF SWALLOWED. WATER REACTIVE.

Health Rating: 1 -Mild
Flammability Rating: 0 - None
Reactivity Rating: 2 –Moderate (Water-Reactive)
Contact Rating: 2 – Moderate (Corrosive)
Lab Protective Equip: GOGGLES; LAB COAT; VENT HOOD; PROPER GLOVES; CLASS D EXTINGUISHER.
Storage Color Code: Orange (General Storage) --------------------------------------------------------------------------------------------------

Potential Health Effects

----------------------------------

Inhalation:

May cause mild irritation to the respiratory tract.

Ingestion:

Corrosive material. Will react immediately with saliva to cause burns and possible local combustion.
Skin Contact:
May cause mild irritation and redness.

Eye Contact:

May cause mild irritation, possible reddening.

Chronic Exposure:

Long-term exposure to photoluminescent powder dust may result in mild fibrosis (scarring of the lungs).
Aggravation of Pre-existing Conditions:
Persons with pre-existing lung disease may be more susceptible to the effects of this substance.

IV. First Aid Measures

Inhalation:

Remove to fresh air. Get medical attention for any breathing difficulty.

Ingestion:

Not expected to require first aid measures. If large amounts were swallowed, give water to drink and get medical advice.
Skin Contact:
Immediately flush skin with plenty of soap and water for at least 15 minutes. Remove contaminated clothing and shoes. Wash clothing before reuse. Thoroughly clean shoes before reuse. Get medical attention if irritation develops. Eye Contact:

Immediately flush eyes with plenty of water for at least 15 minutes, lifting upper and lower eyelids occasionally. Get medical attention if irritation persists.

V Fire Fighting Measures

Fire:

Not considered to be a fire hazard.

Explosion:

Not considered to be an explosion hazard.

Fire Extinguishing Media:

Use dry soda ash, dry salt, sand, graphite powder or metal-fire-extinguishing dry powder such as Met-L-X(R). Do not use water.
Special Information:
In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full facepiece operated in the pressure demand or other positive pressure mode.

VI. Accidental Release Measures

Ventilate area of leak or spill. Wear appropriate personal protective equipment as specified in Section 8. Spills: Sweep up and containerize for reclamation or disposal. Vacuuming may be used to avoid dust dispersal.

VII. Handling and Storage

Keep in a tightly closed container, stored in a cool, dry, ventilated area. Protect against physical damage. Keep away from water. Containers of this material may be hazardous when empty since they retain product residues (dust, solids);

observe all warnings and precautions listed for the product.

VIII. Exposure Controls/Personal Protection

Airborne Exposure Limits:

- OSHA Permissible Exposure Limit (PEL) -
10 mg/m3 (TWA).
- ACGIH Threshold Limit Value (TLV) -
5 mg/m3 (TWA), A4 - Not classifiable as a human carcinogen. Ventilation System:

A system of local and/or general exhaust is recommended to keep employee exposures below the Airborne Exposure Limits. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into the general work area. Please refer to the ACGIH document, Industrial Ventilation, A Manual of Recommended Practices, most recent edition, for details.

Personal Respirators (NIOSH Approved):

If the exposure limit is exceeded, a half-face dust/mist respirator may be worn for up to ten times the exposure limit or the maximum use concentration specified by the appropriate regulatory agency or respirator supplier, whichever is lowest. A full-face piece dust/mist respirator may be worn up to 50 times the exposure limit, or the maximum use concentration specified by the appropriate regulatory agency, or respirator supplier, whichever is lowest. For emergencies or instances where the exposure levels are not known, use a full-facepiece positive-pressure, air-supplied respirator. WARNING: Air-purifying respirators do not protect workers in oxygen-deficient atmospheres.

Skin Protection:

Wear protective gloves and clean body-covering clothing.

Eye Protection:

Use chemical safety goggles and/or full face shield where dusting or splashing of solutions is possible. Maintain eye wash fountain and quick-drench facilities in work area.

IX. Physical and Chemical Properties

Appearance:

yellow-green Powder.

Odor:

Odorless.

Solubility:

Decomposes in water.

Specific Gravity:

3.7~4.1

pH:

ca. 10~11

% Volatiles by volume @ 21C (70F):

0

Boiling Point:

Not applicable.

Melting Point:

1345~1395C

Vapor Density (Air=1):

Not applicable.

Vapor Pressure (mm Hg):

Not applicable.

Evaporation Rate (BuAc=1):

No information found.

X. Stability and Reactivity

Stability:

Becomes dangerous when exposed to moisture, water or incompatibles.

Hazardous Decomposition Products:

Forms strontium hydroxide upon not reacting with water Polymerization: Will not occur.
Conditions to Avoid:
Dusting and incompatibles.

XI. Toxicological Information

Toxicological Data:

No LD50/LC50 information found relating to normal routes of occupational exposure.

XII. Ecological Information Environmental Fate:

No information found.

Environmental Toxicity:

No information found.

XIV. Disposal Considerations

Whatever cannot be saved for recovery or recycling should be managed in an appropriate and approved waste disposal facility. Processing, use or contamination of this product may change the waste management options. State and local disposal regulations may differ from federal disposal regulations. Dispose of container and unused contents in accordance with federal, state and local requirements.

XV. Transport Information

Not regulated.

XVI. Regulatory Information

Australian Hazchem Code: No information found
Poison Schedule: No information found.
WHMIS:
This MSDS has been prepared according to the hazard criteria of the Controlled Products Regulations (CPR) and the MSDS contains all of the information required by the CPR.

XVII. Other Information

NFPA Ratings: Health: 1 Flammability: 0 Reactivity: 0
Label Hazard Warning:
CAUTION! MAY CAUSE IRRITATION TO SKIN, EYES, AND RESPIRATORY TRACT. MAY AFFECT LUNGS.
Label Precautions:
Avoid contact with eyes, skin and clothing.
Washing thoroughly after handling.
Avoid breathing dust.

Keep container closed.
Use with adequate ventilation.
Label First Aid:
In case of contact, immediately flush eyes or skin with plenty of water for at least 15 minutes. Get medical attention if irritation develops or persists. If inhaled, remove to fresh air. Get medical attention for any breathing difficulty.
Product Use:
Laboratory Reagent.
Disclaimer:
United Nuclear Scientific Supplies LLC provides the information contained herein in good faith but makes no representation as to its comprehensiveness or accuracy. This document is intended only as a guide to the appropriate precautionary handling of the material by a properly trained person using this product. Individuals receiving the information must exercise their independent judgment in determining its appropriateness for a particular purpose. UNITED NUCLEAR SCIENTIFIC SUPPLIES LLC & the reseller ChemistryCabinet inc. MAKES NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABIL- ITY, FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THE INFORMATION SET FORTH HEREIN OR
WILL NOT BE RESPONSIBLE FOR DAMAGES RESULTING FROM USE OF OR RELIANCE UPON THIS INFORMATION.***************************************************************** *******************************