What you will receive
•You will receive a 1.8ml glass vial of high quality europium based phosphorescent (glow-in-the-dark) powder. As seen in pictures
The facts
• Produces a beautiful true Aqua glow color.
•Great chemistry gift
• Great for Halloween costumes or Halloween decorations.
•It is a difficult and expensive glow material to make due to the high cost of the exotic chemicals
•Based on the Rare-Earth element Europium
•Europium powder can be recharged indefinitely just by holding it under bright light. Unlike other glow in the darks. 30 hours of glow time after being fully charged.
DISCLAIMER ABOUT PICTURES
•The pictures here do NOT do the glow justice, for the camera can not pick it all the light like our eyes can.
•The first picture shows a fully charged Vial of power in the dark
•The other pictures shows the powder uncharged.
Back to the facts
•This Phosphorescent material is at the cutting edge of chemical phosphorescent technology.
•This is not a cheap weak Chinese glow powder that wont glow a week from now.
•This is high quality yet affordable phosphorescent powder.
•This sample is great for fun science experiments and Collections
Uses
•The powder can be mixed with anything from clear paint, to wax, nail polish, gel, plastics, glaze, the possibilities are endless.
One way ive seen it work with great succuss is since it is a powder it needs to be sprinkled on to the wet nail polish and then after it drys add another coat to protect it from chipping away.
•Use in non-water based paint.
•Paint over a white back ground which will enhance the visible glow. Painting glow paint over a black or dark surface will reduce the visible glow dramatically.
•The Europium powder is quite heat resistant. It can be mixed with glaze and fired in kilns to make pottery & ceramic items alike. Its temperature limit is about 1,200°F or 648.90°C
Safety and toxicity
• Non toxic
• Non radioactive
•Though it is not considerate a toxic do not ingest or inhale or ingest the powder.
Shipping
I offer free shipping to the U.S
Additional Info
MSDS from United Nuclear Scientific Supplies, LLC
125 N. 8th Street Klamath Falls, OR 97601 541-205-6855 sales@unitednuclear.com
_______________________________________________________________________
_______________________________________________________________________
Europium UltraGlow Phosphorescent Powder
_______________________________________________________________________
I. Product Identification
Synonyms: Strontium diluminate activated by europium Chemical Formula: SrAl2O4:Eu,Dy
CAS NO: 12004-37-4 .
24 HR EMERGENCY Telephone Number VelocityEHS (USA): 800-255-3924
II. Composition/Information on Ingredients
Ingredient Percent Hazardous
--------------------------------------- ------- ---------
MSDS
Strontium diluminate activated by europium 99 - 100% Yes
III. Hazards Identification
Emergency Overview
--------------------------
CAUTION! MAY CAUSE IRRITATION TO SKIN, EYES, AND RESPIRATORY TRACT. MAY AFFECT LUNGS. HARMFUL IF SWALLOWED. WATER REACTIVE.
Health Rating: 1 -Mild
Flammability Rating: 0 - None
Reactivity Rating: 2 –Moderate (Water-Reactive)
Contact Rating: 2 – Moderate (Corrosive)
Lab Protective Equip: GOGGLES; LAB COAT; VENT HOOD; PROPER GLOVES; CLASS D EXTINGUISHER.
Storage Color Code: Orange (General Storage) --------------------------------------------------------------------------------------------------
Potential Health Effects
----------------------------------
Inhalation:
May cause mild irritation to the respiratory tract.
Ingestion:
Corrosive material. Will react immediately with saliva to cause burns and possible local combustion.
Skin Contact:
May cause mild irritation and redness.
Eye Contact:
May cause mild irritation, possible reddening.
Chronic Exposure:
Long-term exposure to photoluminescent powder dust may result in mild fibrosis (scarring of the lungs).
Aggravation of Pre-existing Conditions:
Persons with pre-existing lung disease may be more susceptible to the effects of this substance.
IV. First Aid Measures
Inhalation:
Remove to fresh air. Get medical attention for any breathing difficulty.
Ingestion:
Not expected to require first aid measures. If large amounts were swallowed, give water to drink and get medical advice.
Skin Contact:
Immediately flush skin with plenty of soap and water for at least 15 minutes. Remove contaminated clothing and shoes. Wash clothing before reuse. Thoroughly clean shoes before reuse. Get medical attention if irritation develops. Eye Contact:
Immediately flush eyes with plenty of water for at least 15 minutes, lifting upper and lower eyelids occasionally. Get medical attention if irritation persists.
V Fire Fighting Measures
Fire:
Not considered to be a fire hazard.
Explosion:
Not considered to be an explosion hazard.
Fire Extinguishing Media:
Use dry soda ash, dry salt, sand, graphite powder or metal-fire-extinguishing dry powder such as Met-L-X(R). Do not use water.
Special Information:
In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full facepiece operated in the pressure demand or other positive pressure mode.
VI. Accidental Release Measures
Ventilate area of leak or spill. Wear appropriate personal protective equipment as specified in Section 8. Spills: Sweep up and containerize for reclamation or disposal. Vacuuming may be used to avoid dust dispersal.
VII. Handling and Storage
Keep in a tightly closed container, stored in a cool, dry, ventilated area. Protect against physical damage. Keep away from water. Containers of this material may be hazardous when empty since they retain product residues (dust, solids);
observe all warnings and precautions listed for the product.
VIII. Exposure Controls/Personal Protection
Airborne Exposure Limits:
- OSHA Permissible Exposure Limit (PEL) -
10 mg/m3 (TWA).
- ACGIH Threshold Limit Value (TLV) -
5 mg/m3 (TWA), A4 - Not classifiable as a human carcinogen. Ventilation System:
A system of local and/or general exhaust is recommended to keep employee exposures below the Airborne Exposure Limits. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into the general work area. Please refer to the ACGIH document, Industrial Ventilation, A Manual of Recommended Practices, most recent edition, for details.
Personal Respirators (NIOSH Approved):
If the exposure limit is exceeded, a half-face dust/mist respirator may be worn for up to ten times the exposure limit or the maximum use concentration specified by the appropriate regulatory agency or respirator supplier, whichever is lowest. A full-face piece dust/mist respirator may be worn up to 50 times the exposure limit, or the maximum use concentration specified by the appropriate regulatory agency, or respirator supplier, whichever is lowest. For emergencies or instances where the exposure levels are not known, use a full-facepiece positive-pressure, air-supplied respirator. WARNING: Air-purifying respirators do not protect workers in oxygen-deficient atmospheres.
Skin Protection:
Wear protective gloves and clean body-covering clothing.
Eye Protection:
Use chemical safety goggles and/or full face shield where dusting or splashing of solutions is possible. Maintain eye wash fountain and quick-drench facilities in work area.
IX. Physical and Chemical Properties
Appearance:
yellow-green Powder.
Odor:
Odorless.
Solubility:
Decomposes in water.
Specific Gravity:
3.7~4.1
pH:
ca. 10~11
% Volatiles by volume @ 21C (70F):
0
Boiling Point:
Not applicable.
Melting Point:
1345~1395C
Vapor Density (Air=1):
Not applicable.
Vapor Pressure (mm Hg):
Not applicable.
Evaporation Rate (BuAc=1):
No information found.
X. Stability and Reactivity
Stability:
Becomes dangerous when exposed to moisture, water or incompatibles.
Hazardous Decomposition Products:
Forms strontium hydroxide upon not reacting with water Polymerization: Will not occur.
Conditions to Avoid:
Dusting and incompatibles.
XI. Toxicological Information
Toxicological Data:
No LD50/LC50 information found relating to normal routes of occupational exposure.
XII. Ecological Information Environmental Fate:
No information found.
Environmental Toxicity:
No information found.
XIV. Disposal Considerations
Whatever cannot be saved for recovery or recycling should be managed in an appropriate and approved waste disposal facility. Processing, use or contamination of this product may change the waste management options. State and local disposal regulations may differ from federal disposal regulations. Dispose of container and unused contents in accordance with federal, state and local requirements.
XV. Transport Information
Not regulated.
XVI. Regulatory Information
Australian Hazchem Code: No information found
Poison Schedule: No information found.
WHMIS:
This MSDS has been prepared according to the hazard criteria of the Controlled Products Regulations (CPR) and the MSDS contains all of the information required by the CPR.
XVII. Other Information
NFPA Ratings: Health: 1 Flammability: 0 Reactivity: 0
Label Hazard Warning:
CAUTION! MAY CAUSE IRRITATION TO SKIN, EYES, AND RESPIRATORY TRACT. MAY AFFECT LUNGS.
Label Precautions:
Avoid contact with eyes, skin and clothing.
Washing thoroughly after handling.
Avoid breathing dust.
Keep container closed.
Use with adequate ventilation.
Label First Aid:
In case of contact, immediately flush eyes or skin with plenty of water for at least 15 minutes. Get medical attention if irritation develops or persists. If inhaled, remove to fresh air. Get medical attention for any breathing difficulty.
Product Use:
Laboratory Reagent.
Disclaimer:
United Nuclear Scientific Supplies LLC provides the information contained herein in good faith but makes no representation as to its comprehensiveness or accuracy. This document is intended only as a guide to the appropriate precautionary handling of the material by a properly trained person using this product. Individuals receiving the information must exercise their independent judgment in determining its appropriateness for a particular purpose. UNITED NUCLEAR SCIENTIFIC SUPPLIES LLC & the reseller ChemistryCabinet inc. MAKES NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABIL- ITY, FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THE INFORMATION SET FORTH HEREIN OR
WILL NOT BE RESPONSIBLE FOR DAMAGES RESULTING FROM USE OF OR RELIANCE UPON THIS INFORMATION.***************************************************************** *******************************